※ This article was written to provide medical information.
Please note that it is not subject to review under Article 56(2) and
Article 57 of the Medical Service Act, and that it is not a promotional
post unrelated to reviewed content.
Hello,
this is Director Park Jung Keun
of Face Plus Plastic Surgery Clinic.

Have you ever turned your head slightly in front of the mirror
and seen the line of your nasal bridge lean to one side?
If your nose looks crooked in every photo,
you may worry that the implant has bent.
“Did it bend because the implant was carved before it was inserted?”
When you look up a bent nose implant,
this is probably the first question you come to.
The short answer: in many cases,
a bent nose implant cannot be explained
by the carving method alone.
How well the back of the implant fits against the nasal bone
and whether the nasal bones and cartilage
were symmetric to begin with also play a part.
How the membrane around the implant has changed
and at what depth the implant was placed
can also be reasons for bending.
So when considering revision, too,
the right order is to find out first why it tilted
rather than to replace the implant.
If the cause is different, the way to correct it is different too.

| Contents | ||
|
1. Why does a nose implant bend?

A bent nose implant
is a condition in which the implant placed in the bridge
moves off the center line of the face, tilting to one side
or looking curved.
In reality, several factors are often mixed.
The implant may have rotated out of place,
the implant's shape itself may have been pressed into a curve,
or the base under the implant may have been asymmetric to begin with.
The causes most often cited are these.
✔ A gap between the back of the implant and the nasal bone
The contour of the nasal bone surface differs from person to person.
If the back of the implant does not match this curved surface,
a raised space forms, leaving room for the implant to wobble.
✔ Asymmetry of the nasal bones and cartilage
A case report published in 2024 in the journal of the Korean Society of Plastic and Reconstructive Surgeons
(Archives of Plastic Surgery)
cited, as common causes of implant deviation,
asymmetry of the nasal bones and the upper lateral cartilages.
The upper lateral cartilages continue below the nasal bones
and support the middle of the bridge from both sides.
If there is asymmetry across the whole face,
bending can become apparent over time.
✔ Contraction of the capsule around the implant
The body forms a thin membrane around the implant.
If this membrane thickens and shrinks,
the implant can be pulled to one side or pressed and bent.
✔ The depth at which the implant was placed
A bridge implant is usually placed under the membrane covering the nasal bone (periosteum).
If it is placed in a shallower layer,
the implant is known to move more.
✔ External impact and habits
Bumping the nose hard
or a habit of often pushing the implant with your hand
can also cause its position to change.
2. Carved-to-fit implants and custom implants:

A ready-made silicone implant
is an implant made in a set shape
that is carved during surgery to fit the nose.
Length and height are relatively easy to adjust,
but matching by hand even the fine contours of the back
that touches the nasal bone is not easy.
So rather than whether it was carved,
I see how closely the back of the implant sits against the nasal bone
as the issue more closely related to bending.
A custom implant
is designed and made in advance
based on the shape of the nasal bone confirmed by imaging.
A custom implant is considered in cases like these.
✔ When the nasal bone contour is uneven or asymmetric
These are cases in which carving the back of a ready-made implant alone
can hardly reduce the gap.
✔ When a hump nose must be covered rather than shaved
These are cases in which the back of the implant must be designed
to follow the contour of the protruding bone.
✔ When there is a spot where the bone has been indented by a previous implant
The shape of the indentation differs from person to person,
so a design that reflects that contour may be needed.
✔ When it is a revision changing to a design lower or higher than before
A method that sets the desired height and line in advance
and makes the implant to match can help.
On the other hand, there is also bending
that a custom implant alone cannot solve.
If the capsule has thickened and hardened and pulled the implant,
then before changing the implant's shape,
the hardened capsule must also be dealt with.
If inflammation was the cause,
rather than inserting an implant again,
a plan based mainly on autologous tissue is considered first.
If what looks bent is the tip rather than the bridge,
the cartilage structure supporting the tip may be the cause,
so cartilage correction must be considered as well.
3. Should I have surgery again now? What to check first

Visible bending does not always
mean revision is needed right away.
✔ The period when swelling remains after the first surgery
While swelling goes down unevenly,
the nose can look tilted to one side.
During this period, we first watch the tissue settle.
✔ Differences within the range of natural facial asymmetry
Human faces naturally differ slightly between left and right.
Comparing photos taken in the same lighting and at the same angle
helps gauge whether it is an implant problem or a difference in the base.
✔ When it looks very slight and causes no discomfort
If it is barely visible from the front
and there are no signs of inflammation,
regular follow-up is also an option.
Conversely, there are cases that need to be seen right away.
If the nose becomes red and feels warm,
or there is fluid or pain that keeps getting worse,
checking for inflammation comes before the bending.
If the outline of the implant shows through the skin,
or the skin becomes thin and changes color,
it may be a sign that the implant is pressing on the skin,
so do not put it off; get seen.
In a consultation about bending, rather than the shape of the nose,
I first check where the bending started.
✔ Where and how deep the implant sits
With a hands-on examination and imaging,
we see in which layer and to which side the implant has tilted.
✔ Symmetry of the nasal bones and cartilage
Even if the implant is reinserted straight,
it can drift again if the base is tilted,
so we also judge whether the base needs correction.
✔ Capsule condition and presence of inflammation
Depending on whether the capsule has thickened and hardened and whether there are traces of inflammation,
whether to use an implant again
or switch to autologous tissue differs.
✔ Skin thickness
If the skin has thinned,
rather than pushing for implant height,
we plan within the range the skin can withstand.
4. Precautions before and after revision, and

Even after revision for a bent nose implant,
swelling, bruising, asymmetry, and infection can occur,
and the implant may move again
or the capsule may contract.
Even with a custom implant,
these possibilities do not disappear.
The implant may show through
or become exposed through the skin.
Before setting a surgery date,
bring a list of the medications
and supplements you are taking,
and tell us whether you smoke, how well your blood pressure and blood sugar are controlled,
and whether you tend to form thick scars.
For blood-thinning medications such as aspirin,
whether they need adjusting before surgery must be checked in advance,
and smoking works against wound healing and inflammation control.
After surgery, be careful not to bump your nose,
and even if you are curious about the implant's position,
it is better not to push or press it with your hand.
Also check at your follow-up when you can wear glasses again.
If swelling on one side keeps increasing
or redness, warmth, or fluid develops,
you must contact the clinic right away.
During the consultation,
you can also ask questions like these.
✔ Where did my bending start?
Hear an explanation of which of the implant, capsule, nasal bone, or cartilage
is the cause.
✔ Do I need a custom implant in my case?
Hearing both the reasons it is needed and the reasons it is not
makes the decision easier.
✔ Are materials other than an implant possible?
Check whether autologous tissue can be used
and, if so, where it would come from.
✔ Does the doctor who consulted with me also handle the surgery and follow-up?
With bending, the judgment stays consistent only if the person who found the cause
follows it through to the end.
If you are concerned about a bent nose implant,
the one thing to remember
is that before replacing the implant,
you must first find out why it tilted.
Before the consultation, write down when your previous surgery was
and the type of implant used,
and keep a few photos taken in the same lighting from the front and from below,
which makes it easier to compare changes.
If the bending becomes more and more noticeable,
or the nose becomes red and feels warm,
I hope you will not put off a consultation.
- Hours -
Weekdays 9:00 ~ 18:00 Saturday 9:00 ~ 16:00 Public Holidays / Sunday Regular closing day |
- Contact -
| Face Plus Plastic Surgery Clinic | ||
Consultation line: 02-541-8500 Inquiries: Ask via KakaoTalk |
- Directions -